Gas Chromatography

Providing you the best range of gas chromatograph and gas chromatography with effective & timely delivery.

Gas Chromatograph

REQUEST CALLBACK

Gas Chromatograph
Approx. Rs 5.15 Lakh / Piece
Get Best Quote

Thanks for Contacting Us.

Product Details:
Minimum Order Quantity1 Piece
ApplicationIndustrial Use, Laboratory Use
BrandNETEL
ModelANALYTE 2900A
Temperature Accuracy+-1% of set value from 50-500 degree C
Size (HxwxD)290X280X160mm
Volume13.8 L
Temperature5-500 Degree C
Ramp rate0.1-50 degree C/M
No. of ramps10
Cooling rate300-50 degree C within 7 minutes at 25 degree C room temperature
Temperature Gradient2 degree C max (on 200 mm Dia. Circumference, 40 mm from the sensor)
Polarization-240 VDC

Netel, the specialist in Gas-liquid chromatography for last three decades serving Indian and world markets for multiple
Gas-Liquid Chromatography applications. Industries covered are Pharmaceutical, Environment, Petrochemical, Research, Chemical, Agrochemicals.

Netel, has introduced Latest version Advanced Gas Chromatography Model Analyte 2900A with Dual Flame Ionization Detectors and two nos. Split/Split-less injection ports. The electronic pressure controller (EPC) provides excellent performance with capillary columns. Each channel allows complete electronic pressure control that includes the carrier gas, split adjustment & combustion gases namely hydrogen and air for flame ionization detector.

Heated Zones: 5 Independent Heated Zone up to 400 °C for individual control of Injectors, detectors, oven

Pneumatics:
  • The electronic pressure controller (EPC) provides excellent performance with capillary columns. Each channel allows complete electronic pressure control that includes the carrier gas, split adjustment & combustion gases namely hydrogen and air for flame ionization detector.
  • Split /Split-less Injector: Pressure range 0 to 450 kph. Constant Pressure or constant flow settable.
  • Pressure program: Provided
  • Correction Factor: Maintains the constant flow or average linear velocity during oven heating

Injection System:
  • Two Split/split-less (capillary column) injectors. With constant pressure or constant flow mode and pressure program.
  • Temperature range settable up to 400 °C. in the step of 1°C.

Detectors:
  • Higher sensitivity flame ionization detector
  • requires no makeup gas due to unique zero dead volume design Temperature range settable up to 400 °C. in the step of 1 °C.
  • Dynamic range 107
  • Sensitivity equivalent to 3pg C/sec of toluene/nonane.
Yes! I am interested

Gas Chromatography

REQUEST CALLBACK

Gas Chromatography
Approx. Rs 3.25 Lakh / Piece
Get Best Quote

Thanks for Contacting Us.

Product Details:
ApplicationIndustrial Use, Laboratory Use
Size (WxLxH)76x540x58 Hcms
Weight86 Kgs
Power2kW
Voltage220V, 50 Hz

Features:
  • Modular GC
  • Keyboard Control of GC
  • Storage often methods for GC parameters
  • Read a flow technique
  • Keyboard control carrier gas switchover dedicated capillary injector
  • Auto cooling by flap five ramps, six plateaus in the single method
  • Control of 2 external heated zones and 3 programmable relays
  • Dual FID amplifiers
  • Remote flame ignitor
  • Dual path TCD
  • Auto zero facility
  • Audible ready signal
  • Protection circuit for column & TCD filament
  • Choice of several detectors ( FID, TCD, ECD, NPD, FPD ETC.)


Column Oven:
  • Dimensions : 25W x 15D x 35H cms
  • Volume: 13 Litres
  • Temperature stability: ±0.1°C
  • Operating Temperature: Ambient to 400°C in
  • Range: steps of 0.1°C
  • Option: Upgradable to 500°C
  • Cooling speed: 250°C to 50°C in 5 mins. (at 20°C ambient temp.) including stabilization time
  • Overheat protection: Protection circuit actives at 20°C over set temp. at the step of 50°C


Temperature Programmer:
  • Isothermal Temp. range: Ambient to 400° C in, steps ofO.1°C
  • Max. Ramp Rate Programming: Up to 150°C at 30°C/mm. Up to 250°C at 20°C/mm. Up to 325°C at 15°C/mm. Up to 400°C at 10°C/man.
  • Number of Lamps: 5 max.(Hold the ramp rate at any time) 999 mm.
  • Max. Programme length: 999 mm.


Injection System:
  • Single or Dual vertical injectors with Split Splitless
  • converters for 1/4”, 1/8 or capillary columns
  • Operating temp. range: Ambient to 400°C in steps of 0.1°C
  • Dedicated port for capillary columns

Pneumatic System:
  • Keyboard-operated carrier gas change over system
  • Pressure switch cut off mains power in case of depletion of carrier gas flow
  • Differential flow controllers (DFC) for carrier gas with digital readout


Detector:

Flame Ionization Detector :
  • Design: Forced air diffusion
  • Mode: Single or dual column with dual amplifier
  • Operating temp. range: Ambient to 400°C
  • Sensitivity: >0.017 coulombs/gm.
  • Dynamic range: io
  • FID amplifier: Max. sensitivity 5 x 10Amp. Ranges :1,10,100,1000
  • Noise: Below 1 x 1013 Amp


Thermal Conductivity Detector:
  • Design: Dual path, 4. filaments
  • Filaments: Tungsten-Rhenium
  • Mode: Dual column
  • Operating temp. range: Ambient to 400°C in steps of 0.1°C
  • Filament current: 0-400m Arrange
  • Temperature stability: ±0.1°C
  • Sensitivity: 3500 mI.mv I mg at 80°C temperature (resistance)
  • Electronics: Full- bridge (constant temperature resistance), mode, with filament temp.
  • Filament temp.: 150-450°C In steps of 75°C

Additional Information:

  • Item Code: Michro-9100
  • Yes! I am interested

    View PDF

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Netel (India) Limited
    Vishwas Tarve (Sales & Services Head)
    W-408, Near Mahanagar Press, MIDC, Rabale TTC Industrial Area,
    Navi Mumbai - 400701, Maharashtra, India