Send Email
Send SMS
Search
Netel (India) Limited
Netel (India) Limited


GAS LIQUID CHROMATOGRAPHS

NETEL India limited is a leading manufacturer of Gas liquid chromatographs(GLC) since last three decades and supplied more than 2500 systems to various applications such as1.Environmental testing labs, 2.Transformer oil gas analysis 3.Agrochemicals 4.Packaging industries 5.Edible Oil industries 6.Distillaries 7.Bulk drugs 8.Flavors and fragrances 9.Aroma industries 10.chemicals 11.Research labs 12. educational institutes and universities 13.Polymer industries 14.solvent industires 15.petrochemicals 16.Oil and Gas 17.LPG Gas analysis 18.Natural gas analysis 19.Organic chemicals 20.soaps and detergents and many more.
Depending on the applications detectors such as FID,TCD,NPD,ECD and FPD are incorpoarted in the GLC systems.
The clarity chromatography data station is supplied along with the GLC sytem to meet CFR compliant norms.
Clarity is advanced Chromatography Data Station (CDS) with optional software modules for data acquisition, processing and instrument control. Its wide range of data acquisition interfaces (A/D converters, LAN, USB, RS232) allows connection to any GC or LC chromatograph.Up to four independent chromatography systems can be simultaneously connected, each can acquire up to 32 signals.
You can switch any time between English, French, German, Russian, Spanish and Chinese localization.

Control modules provide integrated control of selected instruments such as GCs, pumps, detectors, autosamplers, etc.

Extensions provide functions for specific separation techniques such as PDA, GPC analysis, Mass spectrometry or SST.

Clarity2Goin your iPhone or Android powered mobile devices allows you to monitor running analyses from multiple installations of Clarity.

Clarity comes with extensive free support from DataApex as well as from the growing community of users in the Clarity Forum.


Gas Chromatograph

REQUEST CALLBACK

Gas Chromatograph
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 5.15 Lakh / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Temperature Accuracy+-1% of set value from 50-500 degree C
Size (HxwxD)290X280X160mm
Volume13.8 L
Temperature5-500 Degree C
Ramp rate0.1-50 degree C/M
No. of ramps10
Cooling rate300-50 degree C within 7 minutes at 25 degree C room temperature
Temperature Gradient2 degree C max (on 200 mm Dia. Circumference, 40 mm from the sensor)
Polarization-240 VDC
BrandNETEL
ModelANALYTE 2900A
ApplicationIndustrial Use, Laboratory Use

Netel, the specialist in Gas-liquid chromatography for last three decades serving Indian and world markets for multiple
Gas-Liquid Chromatography applications. Industries covered are Pharmaceutical, Environment, Petrochemical, Research, Chemical, Agrochemicals.

Netel, has introduced Latest version Advanced Gas Chromatography Model Analyte 2900A with Dual Flame Ionization Detectors and two nos. Split/Split-less injection ports. The electronic pressure controller (EPC) provides excellent performance with capillary columns. Each channel allows complete electronic pressure control that includes the carrier gas, split adjustment & combustion gases namely hydrogen and air for flame ionization detector.

Heated Zones: 5 Independent Heated Zone up to 400 °C for individual control of Injectors, detectors, oven

Pneumatics:
  • The electronic pressure controller (EPC) provides excellent performance with capillary columns. Each channel allows complete electronic pressure control that includes the carrier gas, split adjustment & combustion gases namely hydrogen and air for flame ionization detector.
  • Split /Split-less Injector: Pressure range 0 to 450 kph. Constant Pressure or constant flow settable.
  • Pressure program: Provided
  • Correction Factor: Maintains the constant flow or average linear velocity during oven heating

Injection System:
  • Two Split/split-less (capillary column) injectors. With constant pressure or constant flow mode and pressure program.
  • Temperature range settable up to 400 °C. in the step of 1°C.

Detectors:
  • Higher sensitivity flame ionization detector
  • requires no makeup gas due to unique zero dead volume design Temperature range settable up to 400 °C. in the step of 1 °C.
  • Dynamic range 107
  • Sensitivity equivalent to 3pg C/sec of toluene/nonane.
Yes! I am interested

Gas Chromatography

REQUEST CALLBACK

Gas Chromatography
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3.25 Lakh / PieceGet Latest Price

Product Details:
Size (WxLxH)76x540x58 Hcms
Weight86 Kgs
Power2kW
Voltage220V, 50 Hz
ApplicationIndustrial Use, Laboratory Use

Features:
  • Modular GC
  • Keyboard Control of GC
  • Storage often methods for GC parameters
  • Read a flow technique
  • Keyboard control carrier gas switchover dedicated capillary injector
  • Auto cooling by flap five ramps, six plateaus in the single method
  • Control of 2 external heated zones and 3 programmable relays
  • Dual FID amplifiers
  • Remote flame ignitor
  • Dual path TCD
  • Auto zero facility
  • Audible ready signal
  • Protection circuit for column & TCD filament
  • Choice of several detectors ( FID, TCD, ECD, NPD, FPD ETC.)


Column Oven:
  • Dimensions : 25W x 15D x 35H cms
  • Volume: 13 Litres
  • Temperature stability: ±0.1°C
  • Operating Temperature: Ambient to 400°C in
  • Range: steps of 0.1°C
  • Option: Upgradable to 500°C
  • Cooling speed: 250°C to 50°C in 5 mins. (at 20°C ambient temp.) including stabilization time
  • Overheat protection: Protection circuit actives at 20°C over set temp. at the step of 50°C


Temperature Programmer:
  • Isothermal Temp. range: Ambient to 400° C in, steps ofO.1°C
  • Max. Ramp Rate Programming: Up to 150°C at 30°C/mm. Up to 250°C at 20°C/mm. Up to 325°C at 15°C/mm. Up to 400°C at 10°C/man.
  • Number of Lamps: 5 max.(Hold the ramp rate at any time) 999 mm.
  • Max. Programme length: 999 mm.


Injection System:
  • Single or Dual vertical injectors with Split Splitless
  • converters for 1/4”, 1/8 or capillary columns
  • Operating temp. range: Ambient to 400°C in steps of 0.1°C
  • Dedicated port for capillary columns

Pneumatic System:
  • Keyboard-operated carrier gas change over system
  • Pressure switch cut off mains power in case of depletion of carrier gas flow
  • Differential flow controllers (DFC) for carrier gas with digital readout


Detector:

Flame Ionization Detector :
  • Design: Forced air diffusion
  • Mode: Single or dual column with dual amplifier
  • Operating temp. range: Ambient to 400°C
  • Sensitivity: >0.017 coulombs/gm.
  • Dynamic range: io
  • FID amplifier: Max. sensitivity 5 x 10Amp. Ranges :1,10,100,1000
  • Noise: Below 1 x 1013 Amp


Thermal Conductivity Detector:
  • Design: Dual path, 4. filaments
  • Filaments: Tungsten-Rhenium
  • Mode: Dual column
  • Operating temp. range: Ambient to 400°C in steps of 0.1°C
  • Filament current: 0-400m Arrange
  • Temperature stability: ±0.1°C
  • Sensitivity: 3500 mI.mv I mg at 80°C temperature (resistance)
  • Electronics: Full- bridge (constant temperature resistance), mode, with filament temp.
  • Filament temp.: 150-450°C In steps of 75°C

Additional Information:

  • Item Code: Michro-9100
  • Yes! I am interested

    View PDF

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Netel (India) Limited
    V.M. Shanbhag (Divisional Head)
    W-408, Near Mahanagar Press, MIDC TTC Industrial Area, Rabale,
    Navi Mumbai - 400701, Maharashtra, India
    Call Us: 
    Call Response Rate: 90%
    Share Us :
    F G T L



    Home  |   Profile   |  Products & Services  |  Site Map  |   Contact Us   |   Mobile Site

    © Netel (India) Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited